Power medical instrumentation high isolation anti-surge type power supply module (WRE/WRF/WRH/WRFH/WDH etc.)

<
>
  • 14.8KV antistatic 3KV isolated single regulated output overload protection power supply : WRF-H series

  • WRF-H series is specially designed for power (load) management terminal power dispatching instrument. Mainly used in electrical equipment ground interference suppression, 485 external port power isolation and conversion of instruments and meters, and safety high isolation/anti-surge/anti-static isolation of the exposed metal parts of the instrument shell interface terminals.

SunYuan technology development and production of energy meters dedicated 6KVAC high isolation anti-static DC/DC converter, is a high electrical isolation and anti-surge, anti-static characteristics, and the output of the output has a self-recovery overload and short-circuit and 8KV anti-static protection function of the national patent products (Patent No.: ZL 200420042857.1). Recently, this product has successfully passed the high isolation/anti-surge/anti-static test in the technical inspection related to the safety of the external RS485/RS232 interface of the power load management control terminal (user management terminal) instrument with high isolation (4500V) and anti-static (direct contact of the external terminal: 8000V). At present, it has been widely used in the power instrumentation manufacturing industry.

   Typical applications of DC-DC power modules (modular power supply), voltage polarity conversion, selection of external filter capacitors, overload and short-circuit protection circuits and series-parallel use are described in detail. Correct use can extend the service life of the product to avoid interference, overheating, self-excitation, poor start-up and other phenomena and irreparable damage.

 

Product Technical Parameters


Input Voltage          

5, 12, 15, 24 VDC

Output Voltage                                 

3.3,5,9,12,15VDC

For other specifications, please consult with Shunyuan Technology Co.

 

Electrical Characteristics

The following data are measured at TA=25° C, nominal input voltage, and rated output current unless otherwise noted.

 

Input Characteristics

Voltage Range +/- 10%* nominal 

Filtering Ceramic Capacitors

 

Isolation Characteristics

 

Voltage 6000 VAC

Leakage Current 1 mA

Resistance 109 Ohm

Capacitance 60 pF type.

 

Output Characteristics

Electrostatic rating ≥8000V

Voltage Accuracy +/- 2%* Nominal Max.

( 20 MHz BW) Ripple and Noise 50mV p-p, max. 

Sustained short-circuit time Long-term

Linear Voltage Calibration +/- 1.2% / 1.0% of Vin

Load Voltage Calibration +/- 8 %, load = 20 ~ 100

Temperature Coefficient +/- 0.02%/°C  

 

General Characteristics

Efficiency 70% to 80  

Switching Frequency 80 - 125KHz  

 

Environmental Characteristics

Operating temperature (ambient) - 40° C to + 85° C  

Storage temperature - 55 °C to + 125 °C  

Reduced nominal value See temperature characteristics graph

Humidity ≤ 90%, uncompressed

Cooling method Natural air cooling

 

Volume Characteristics

SIP package size 19.50 x 9.80 x 12.50 mm

 

                                                          0.77 x 0.39 x 0.49 in.

 

Weight 4 - 6 g

 

Case Material Non-Conductive Flame Retardant Black Plastic


8KV Anti-Static 3KV Isolated Regulated Single Output Overload Protection Power Module: WRF-H Series

  • Homepage
  • Product Display
  • Qualification Certificate
  • Application Information
  • Business Consulting
  • phone:0086-755-83100080 / 83100110 / 83150723


    fax:0086-755-83116652


    mailbox:sy@sunyuansz.net


    address:Floor 2, building 6, East 1st Industrial Park, Zhonghuan Road, Minzhi street, Longhua District, Shenzhen


    Copyright©2013-2021 Shunyuan Technology All Rights Reserved copyright 粤ICP05061957号 technical support:图页网 xml html